<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>trippingg unit - Elmi-Elektronik &amp; SBE-Schrader-Bergbau-Elektrik</title>
	<atom:link href="https://elmi-elektronik.com/product-tag/trippingg-unit/feed/" rel="self" type="application/rss+xml" />
	<link>https://elmi-elektronik.com</link>
	<description>Elektronikmodule f&#252;r Bergbau-, Chemie- und &#214;lindustrie. Einsatz in explosionsgef&#228;hrdeten Bereichen.</description>
	<lastBuildDate>Thu, 30 Oct 2025 22:48:23 +0000</lastBuildDate>
	<language>de</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://i0.wp.com/elmi-elektronik.com/wp-content/uploads/2025/09/cropped-3-2.png?fit=32%2C32&#038;ssl=1</url>
	<title>trippingg unit - Elmi-Elektronik &amp; SBE-Schrader-Bergbau-Elektrik</title>
	<link>https://elmi-elektronik.com</link>
	<width>32</width>
	<height>32</height>
</image> 
<site xmlns="com-wordpress:feed-additions:1">248771988</site>	<item>
		<title>Over-current tripping unit IB4.1</title>
		<link>https://elmi-elektronik.com/product/over-current-tripping-unit-ib4-1/</link>
		
		<dc:creator><![CDATA[admin]]></dc:creator>
		<pubDate>Wed, 17 Sep 2025 14:24:36 +0000</pubDate>
				<guid isPermaLink="false">https://elmi-elektronik-se4btndj70.live-website.com/?post_type=product&#038;p=203</guid>

					<description><![CDATA[<p>Together with suitable transformers (1mV/A to 10mV/A), the electronic over-current tripping unit IB4.1 is intended as over-current protection of electrical sub-surface equipment.</p>
<p>The post <a href="https://elmi-elektronik.com/product/over-current-tripping-unit-ib4-1/">Over-current tripping unit IB4.1</a> first appeared on <a href="https://elmi-elektronik.com">Elmi-Elektronik & SBE-Schrader-Bergbau-Elektrik</a>.</p>]]></description>
										<content:encoded><![CDATA[<h1><span style="color: #ff9900;">Over-current tripping unit IB4.1</span></h1>
<p>&nbsp;</p>
<h3></h3>
<h3 style="text-align: left;">Original version of the operating instructions</h3>
<p>&nbsp;</p>
<h6>ELMI article number 01104000</h6>
<p>&nbsp;</p>
<h4><span class="Y2IQFc" lang="en" style="color: #99ccff;">Note: </span></h4>
<h4 id="tw-target-text" class="tw-data-text tw-text-large tw-ta" dir="ltr" tabindex="-1" role="text" data-placeholder="Translation" data-ved="2ahUKEwj_x82NhcKQAxWPgv0HHVBvEdoQ3ewLegQIDBAU" aria-label="Translated text: Note: “Operating instructions will be sent with purchase.”"><span class="Y2IQFc" lang="en" style="color: #99ccff;">“The operating instructions and further technical data will be sent with your purchase.”</span></h4>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>ELMI-Elektronik GmbH</strong><br />
Höfer Ohl 12, 51645 Gummersbach<br />
Registered at Cologne District Court HRB 45688</p>
<p>Managing Directors: Walter Schrader / Cathrin Schmitt ppa<br />
VAT ID DE 241143449 • Tax No. 212/5724/2111<br />
Tel.: +49 (0)2261 / 994260 &#8211; 50 • Fax: +49 (0)2261 / 994260 &#8211; 60 02261-994260 50</p>
<p>Head Office 02261-994260 60 Fax 02261-994260 51 &#8211; Technology/Production<br />
Elmi-elektronik@t-online.de<br />
walter.schrader.gm@sbe-schrader.de<br />
cathrin.schmitt@sbe-schrader.de</p>
<p>S<strong>BE Schrader Mining Electrical</strong><br />
Höfer Ohl 12, 51645 Gummersbach<br />
Tel.: +49 (0)2261 / 92053 &#8211; 0 • Fax: +49 (0)2261 / 92053 &#8211; 29<br />
sbe@sbe-schrader.de • www.sbe-schrader.de<br />
walter.schrader.gm@sbe-schrader.de<br />
cathrin.schmitt@sbe-schrader.de</p>
<p>&nbsp;</p>
<p><strong>General information on the over-current tripping unit IB4.1</strong></p>
<p>&nbsp;</p>
<p>Together with suitable transformers (1mV/A to 10mV/A), the electronic over-current tripping unit IB4.1 is intended as over-current protection of electrical sub-surface equipment. It is characterised by low amounts of self-heating and a huge current setting range both for chronologically delayed over-current tripping (Ith tripping) and for short-circuit quick tripping. It monitors the presence of 3 phases with approx. 120° offset; otherwise, the section is interrupted by Ith monitoring and an alarm contact can report the de-energised condition of the corresponding relay. An analogue value provides 0-10V according to 0.07&#8230;1.4 x IN.</p>
<p>&nbsp;</p>
<p>Transformer constant                            8,6mV/A</p>
<p>Working range In                                   0,8- 80A</p>
<p>Transformer constant                            3mV/A</p>
<p>Working range In                                   2,3- 345A</p>
<p>Transformer constant                            1mV/A</p>
<p>Working range In                                   7- 1050A</p>
<p>&nbsp;</p>
<p>Relapse time upon tripping                    2….3 min</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>Manufacturer&#8217;s address</strong></p>
<p>SBE-Schrader Bergbau Elektrik<br />
Höfer Ohl 12<br />
51645 Gummersbach, Germany</p>
<p><strong>Owner of the distribution rights</strong></p>
<p>ELMI Elektronik GmbH<br />
Höfer Ohl 12<br />
D-51645 Gummersbach</p>
<p><strong>Contact</strong></p>
<p>Phone: +49 (0)2261-92053-0<br />
Fax: +49 (0)2261-92053-29<br />
Email: SBE@SBE-Schrader.de<br />
Email: ELMI-Elektronik@t-online.de</p>
<p><strong>Spare parts and customer service</strong></p>
<p>See manufacturer&#8217;s address</p>
<p><strong>Copyrights and intellectual property rights</strong></p>
<p>Any copyrights and intellectual property rights for the over-current tripping unit IB4.1 shall<br />
be held by SBE-Schrader Bergbau Elektrik.</p>
<p>&nbsp;</p>
<p><strong>1.2 Warranty and liability</strong></p>
<p>As a matter of principle, our &#8222;General Terms and Conditions of Sale and Delivery&#8220; shall be<br />
applicable. Warranty and liability claims in the event of personal and/or material damage<br />
shall be excluded if these can be attributed to one or several of the following causes:</p>
<p><strong>1.3 Intended use</strong></p>
<p>The over-current tripping unit IB4.1 is designed exclusively for the application options<br />
allowed for by the manufacturer.<br />
Any use exceeding the aforementioned shall be deemed improper. The manufacturer shall<br />
not assume any liability for damages resulting thereof. The risk shall be borne exclusively<br />
by the operator.<br />
The concept of intended use also comprises the compliance with the operating,<br />
maintenance, and repair conditions specified by the manufacturer.</p>
<p><strong>1.4 Intended use</strong></p>
<p>In connection with the related transformers, the over-current tripping unit IB4.1 serves for<br />
the protection of electrical consumers regarding the effects of overload and short circuit.<br />
When being used in sub-surface mines, the over-current tripping unit IB4.1 must be<br />
installed into a housing of the ignition protection type &#8222;Flameproof enclosure d&#8220; pursuant to<br />
EN 60079-1.<br />
The concept of intended use also comprises the observance of and compliance with any<br />
information and instructions from these operating instructions, as well as the observance of<br />
the relevant accident prevention regulations by the user at the application site.<br />
<img data-recalc-dims="1" decoding="async" class="alignnone wp-image-132 size-full" src="https://i0.wp.com/elmi-elektronik-se4btndj70.live-website.com/wp-content/uploads/2025/09/Ausrufezeichen.jpg?resize=109%2C96&#038;ssl=1" alt="Over-current tripping unit SB430ST" width="109" height="96" />Improper use may result in dangers. The liability for dangers<br />
and damage resulting from improper use shall be borne<br />
exclusively by the user.</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p><strong>1.5 Structural Modification</strong></p>
<p>It is inadmissible to implement any structural changes to the over-current tripping unit IB4.1.<br />
Unauthorised conversions to the over-current tripping unit IB4.1 are strictly forbidden.</p>
<p>&nbsp;</p>
<pre id="tw-target-text" class="tw-data-text tw-text-large tw-ta" dir="ltr" tabindex="-1" role="text" data-placeholder="Translation" data-ved="2ahUKEwj_x82NhcKQAxWPgv0HHVBvEdoQ3ewLegQIDBAU" aria-label="Translated text: Note: “Operating instructions will be sent with purchase.”"></pre>
<p>&nbsp;</p>
<p><a href="https://elmi-elektronik-se4btndj70.live-website.com/product/over-current-tripping-unit-ib4-1/"><strong><span style="color: #99ccff;">GO BACK UP !</span></strong></a></p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p>
<p>&nbsp;</p><p>The post <a href="https://elmi-elektronik.com/product/over-current-tripping-unit-ib4-1/">Over-current tripping unit IB4.1</a> first appeared on <a href="https://elmi-elektronik.com">Elmi-Elektronik & SBE-Schrader-Bergbau-Elektrik</a>.</p>]]></content:encoded>
					
		
		
		<post-id xmlns="com-wordpress:feed-additions:1">203</post-id>	</item>